Code Length Options
IMPORTANT: This must be completed with the Safe Door in the open position and before any other programming
NOTE: This operation must be performed with the SAFE DOOR OPEN and with access to the back of the lock, as a mechanical reset must be performed during this programming sequence.
The ProLogic Series allows you the ability to select the code length for all safe lock operators and the total number of users allowable on the lock. Setting the code length and number of Users is a global setting and applies to all safe lock operators.
Note: If you skip this step and program the lock, you can change the Code Length/Number of Users at a later time. All safe doors must be opened to make this change as a reset will be required on all lock bodies. All programming will be deleted and the lock will be set back to default.
There are 3 code length options available as follows:
Code Length 6 digits: | 10 total codes available - This is the default mode and meets the UL requirement. |
Code Length 8 digits: | 30 total codes available. This mode also meets the UL requirement. |
Code Length 6 digits: | 30 total codes available. This mode does not meet the UL requirement. |
PW L – 6; Users – 10 – This is the default mode
NOTE: This operation must be performed with the SAFE DOOR OPEN and with access to the back of the lock, as a mechanical reset must be performed during this programming sequence.
Step1: Press the Menu/OK button.
Step 2: Using the ñ and ò, scroll to the System Menu and Press Menu/OK.
Step 3: The display will prompt you to enter a valid code. Enter the Super Code (ID00) only . This function is not available to Manager Codes ID01 or ID02. The “Select Menu” message will be displayed as follows:
Step 4: Scroll ñ and ò to the menu selection “PW L – 6; Users – 10” and Press OK
Step 5: The LCD will display a warning followed by “Delete All Users?”, press OK to confirm.
All users have been deleted.
IMPORTANT: The LCD will advise if a reset is required to finalize the programming. If required, follow the Mechanical Reset procedure outlined in 15.4 Mechanical Reset.
The code length will now be 6 digits and the total available users will be 10.
The Super Code ID00 will now be 1-1-1-1-1-1
The Manager Code ID01 will now be 1-2-3-4-5-6
The Default Recovery Code will be 9-9-9-9-9-9
The Default Encryption Code will be 6-8-5-1-9-8
PW L – 8; Users – 30
NOTE: This operation must be performed with the SAFE DOOR OPEN and with access to the back of the lock, as a mechanical reset must be performed during this programming sequence.
Step1: Press the Menu/OK button.
Step 2: Using the ñ and ò, scroll to the System Menu and Press Menu/OK.
Step 3: The display will prompt you to enter a valid code. Enter the Super Code (ID00) only . This function is not available to Manager Codes ID01 or ID02. The “Select Menu” message will be displayed as follows:
Step 4: Scroll ñ and ò to the menu selection “PW L – 8; Users – 30” and Press OK
Step 5: The LCD will display a warning followed by “Delete All Users?”, press OK to confirm.
All users have been deleted.
IMPORTANT: The LCD will advise if a reset is required to finalize the programming. If required, follow the Mechanical Reset procedure outlined in 15.4 Mechanical Reset.
The code length will now be 8 digits and the total available users will be 30.
The Super Code ID00 will now be 1-1-1-1-1-1-0-0
The Manager Code ID01 will now be 1-2-3-4-5-6-0-0
The Default Recovery Code will be 9-9-9-9-9-9-0-0
The Default Encryption Code will be 6-8-5-1-9-8-0-0